Baumuller鮑米勒維修驅(qū)動(dòng)器修理:
2015:Current is still flowing, the relay may not be switched off
電流仍在流動(dòng),繼電器可能無(wú)法關(guān)閉。
The active mains rectifier unit tried to separate the device from the mains; thereby still a peak current of greater than 10 A was detected. 有源市電整流器單元試圖將設(shè)備與市電分離;從而仍然檢測(cè)到大于10A的峰值電流。
This error cannot be reset.
無(wú)法重置此錯(cuò)誤。
The device must be restarted.
必須重新啟動(dòng)設(shè)備。
Possible causes:
可能的原因:
The DC link is still loaded although the "ready-for-use"-signal on the signal bus and the signal "control ready-for-use" have dropped.盡管信號(hào)總線上的“可供使用”信號(hào)和“可供控制”信號(hào)已下降,但直流鏈路仍處于加載狀態(tài)。